Xthetic® cold extra

Cold-curing denture base resin with extended processing phase

Denture Base Resin, Autopolymer. Acrylic resin for the fabrication of removable or fixed dentures by using the pouring technique.

Xthetic cold extra Autopolymerisat Prothesenkunststoff mit langer Verarbeitungsbreite

Indications

  • Completion of framework dentures
  • Fabrication of full dentures using the pouring technique
  • Partial or total relinings (indirect method)
  • Additions and repairs

Product features

  • universal use
  • very long processing time
  • very good flowability
  • very good mucous membrane compatibility
  • physiological shades and absolute color stability
  • Cadmium free
  • evaluated and certified biocompatibility

Mixing ratio:
10g of powder with 7g of liquid

Processing times:
Swelling phase: approx. 30 sec
Pouring phase: approx. 3 min
Plastic phase: approx. 20 min

Polymerization:
The polymerization is carried out under a pressure of 2-3 bar and a water temperature of 45°C for about 15 minutes.

Shades:
The material is available in colorless/clear, pink, pink V (veined), pink TL (translucent), pink TLV (translucent veined) and pink opaque.

Delivery forms:
Powder: 1.000g, 5.000g
Liquid: 500ml, 5.000ml
additional sizes upon request

Note:
Medical Device. Classification according to ISO 20795-1, Type 2 group 1 and according to MDD 93/42/EEC Annex IX, Class IIa for removable and for fixed dentures.


mechanical properties acc. to ISO 20795-1 Requirements Xthetic® cold extra
Ultimate flexural strength in MPa min. 60 75
Flexural modulus in MPa min. 1500 2400
Maximum stress intensity factor in MPa not required -
Total fracture work in J/m² not required -
additional properties acc. to ISO 20795-1 Requirements Xthetic® cold extra
Water absorption in μg/mm³ max. 32 22
Solubility in μg/mm³ max. 8,0 1,8
Residual monomer in % max. 4,5 3,8
other requirements Xthetic® cold extra
ISO 20795-1 Requirements concerning the packing plasticity not required
ISO 20795-1 Requirements concerning the surface characteristics and the shape capability fulfilled
ISO 20795-1 Requirements concerning the color and the color stability fulfilled
ISO 20795-1 Requirements concerning the translucency and the freedom from porosity fulfilled
ISO 20795-1 Requirements concerning the bonding to synthetic polymer teeth fulfilled
ISO 10993 Requirements concerning the biocompatibility fulfilled